Add to Cart
4 T/H 4000kg Industrial Gas & Oil Fired Horizontal Steam Boiler For Saunas Laundry
Model: industrial gas oil fired steam boiler
Structure:horizontal fire tube, wet back, three pass
Steam Capacity:1-20ton/hour
Steam Pressure:1.0Mpa(10bar),1.25Mpa(13bar),1.6Mpa(16bar),2.5Mpa(25bar)
Steam Temperature:184 °c,194°c, 204°c,226°c(As long as the steam temperature you need is lower than 226°c, we can do it).
Fuel:heavy oil, light oil, natural gas, city gas, lpg,lng,etc
Application: textile mill, food, beer and brewery factory,chemical industry, garment factory, printing mill, paper masking industry,milk pasteurization, pharmaceutical industry etc.
WNS series is a classical shell type steam boiler, with classical design: firetube+ wetback+ 3pass. Its average thermal efficiency >95%, design working life span more than 15 years. Equipped with well-known auxiliary parts, such as BALTUR/RIELLO- Burner, DANFOSS- Pressure Controler, SIEMENS- PLC operation system, LEO- Multistage Pump, etc. to ensure the boiler's steady performance. The entire system warranty period: 2 Years.
When industrial steam boiler goes out of the factory, it is composed of three parts: the main boiler, the chimney and the pipeline system. The main body and the chimney have been manufactured in the factory, and the supporting pipeline valves and instruments of the main boiler have been installed randomly, and then transported to the site to assemble the main body and the chimney.On the spot connect the air source, power supply and water pipeline to start the test.Greatly shorten the installation cycle, and can guarantee the quality of boiler.
Technical Parameter
Boiler Model | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | WNS8 | WNS10 | WNS15 | WNS20 | |
Rated steam capacity(T/H) | 0.5 | 1 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 20 | |
Rated steam pressure(Mpa) | 1.0/1.25/1.6/2.5 | ||||||||||
Rated steam temperature(℃) | 184/194/204/226 | ||||||||||
Feed water temperature(℃) | 20/104 | ||||||||||
Thermal efficiency(%) | >98 | ||||||||||
Nox emission(mg/m3) | 120/80/30 | ||||||||||
Exhaust gas temperature(℃) | <60 | ||||||||||
Fuel type | Light diesel oil/Heavy oil/Natural gas/Liquefied gas/City gas | ||||||||||
Fuel consumption | Light diesel oil(kg/h) | 32.5 | 64.6 | 129.3 | 192.9 | 258.2 | 388.6 | 514.6 | 641.7 | 960.1 | 1276.2 |
Natural gas(Nm3/h) | 35.7 | 70.1 | 140.3 | 212.1 | 283.4 | 424.2 | 566.3 | 707.8 | 1061.7 | 1415.8 | |
Max transportation weight(t) | 3.5 | 5.5 | 8.0 | 10.7 | 11.6 | 17.5 | 22.5 | 26.8 | 35.2 | 45.5 |
Performance advantage
1. Boiler design
Horizontal internal combustion three return journey full wet back design, 100% corrugated furnace, with good thermal retrability, water cooled retrorse chamber, retrorse chamber and back tubeplate butt joint, lowest stress, more reliable quality.
2, large diameter corrugated furnace
The boiler combustion chamber is composed of a large diameter full ripple furnace with large combustion space, complete fuel combustion, effective heat absorption and thermal expansion, and large radiation heating surface.
3. Sufficient heat
The heating area of the boiler is designed to be more than 25 square meters/ton, fully absorbing effective heat, low smoke exhaust temperature, small heat loss, ensuring sufficient output and high efficiency.
4. Steam quality
Pot shell diameter, large water capacity, strong adaptability to load changes, stable output, steam space volume, soda interface and steam outlet net distance is high, low steam humidity.
5. Multi-functional safety and explosion protection device
The back plate of the boiler is equipped with the explosion-proof device which is connected with the furnace to prevent the high energy of the discharge moment when the fuel is violently deflated in the furnace, and it can automatically reset. Meanwhile, it has the function of the fire-viewing mirror and the maintenance channel. It makes use of the adjustment of the burning flame in operation, and makes the furnace inspection and maintenance convenient.
6. Safe precipitation time is sufficient
The combustion chamber of the boiler is arranged and the water level is determined in accordance with the national regulations. At the same time, it is strictly in accordance with the time requirements of the water level fluctuation standard of the international general norms. It has sufficient safe precipitation space to ensure the operation safety of the boiler.
7. Boiler maintenance is convenient
The top of the boiler is provided with manhole, and the front and rear of the boiler is provided with hand hole device, which is convenient for inspecting and cleaning the device inside the boiler and the bottom of the boiler.
8. Unique seal of front and rear smoke box
Smoke box with double open door, easy to open, multi-level labyrinth seal, special sealing material, good compression performance, completely prevent smoke leakage, can be used again.
9. Reliable protection of pressure and water level
Multiple control protection for boiler pressure and water level, as well as ultra-smoky temperature protection ensure the safety of boiler operation.
10. Advanced level of automatic control
The boiler controller is made of Siemens and Delixi electric components with reliable performance.Chinese and English menu with LCD display, touch screen with remote control.
Boiler picture